I/P Transducer Application of Model-BasedWear Detection and Estimation using Steady State Conditions

Christopher Teubert and Matthew J. Daigle
Submission Type: 
Full Paper
AttachmentSizeTimestamp
phmc_13_029.pdf699.03 KBSeptember 11, 2013 - 3:22pm

For modern systems, wear estimation plays an important role in preventing failure, scheduling maintenance, and improving utility. Wear estimation relies on a series of sensors, measuring the state of the system. In some components, the sensors used to estimate wear may not be fast enough to capture brief transient states that are indicative of wear. For this reason it is beneficial to be capable of detecting and estimating the extent of component wear using steady state measurements. This paper details a method for estimating component wear using steady state measurements, and describes a case study of a current/pressure (I/P) transducer. I/P Transducer nominal and off-nominal behavior are characterized using a physics-based model, and validated against expected component behavior. This model is used to determine steady state responses to many common I/P Transducer wear modes.

Publication Year: 
2013
Publication Volume: 
4
Publication Control Number: 
029
Page Count: 
7
Submission Topic Areas: 
Model-based methods for fault detection, diagnostics, and prognosis